2408i Optional Configuration Code
6100XIO Paperless Chart Recorder Configurator

SENSOR INPUT

1
2
3
4
5
6
7
8
A
B
C
D
E
F

Ni/Ni18%Mo Thm'cple
Pt20%Rh/Pt40%Rh Thm'cple
W/W26%Re Thm'cple
W/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
Pt10%Rh/Pt40%Rh Thm'cple
Exegen K80 I.R.Pyrometer
4 to 20mA Linear
B Thm'cple Pt/Pt30%Rh -6%Rh
*C Thm'cple W5%Re/W26%Re
D Thm'cple W3%Re/W25%Re
E Thermocouple
-100 to +100mV Linear

J
K
L
M
N
P
R
S
T
V
W
X
Y
Z

J Thermocouple
K Thermocouple
L Thermocouple
-12 to 80mV Linear
N Thm'cple Nicrosil/NiSil
Platinel II Thm'cple
R Thm'cple Pt/Pt13%Rh
S Thm'cple Pt/Pt10%Rh
T Thermocouple
1 to 10Vdc Linear
1 to 5Vdc Linear
Non Standard
1 to 20mA Linear
RTD/PT100 DIN 43759

MINIMUM RANGE

 *

User defined range

   

MAXIMUM RANGE

 *

User defined range

   

DISPLAY UNITS

C
F

Centigrade
Fahrenheit

K
X

Kelvin
Blank

DIGITAL I/P 1

XX
AC
KL
SR
PV

Disabled
Alarm Acknowledge
Keylock
Remote Setpoint Input
Select Process Value I/P 2

J1
J2
J3
J4

Tare Correct Strain Gauge 1
Tare Correct Strain Gauge 2
Auto Calibration Strain Gauge1
Auto Calibration Strain Gauge2

DIGITAL I/P 2

XX
AC
KL
SR
PV

Disabled
Alarm Acknowledge
Keylock
Remote Setpoint Input
Select Process Value I/P 2

J1
J2
J3
J4
M3

Tare Correct Strain Gauge 1
Tare Correct Strain Gauge 2
Auto Calibration Strain Gauge1
Auto Calibration Strain Gauge2
CTX Mode 4

SENSOR INPUT

J
K
T
L
N
R
S
B
P
C
Z
D
E
1
2

Default Configuration
J Thermocouple
K Thermocouple
T Thermocouple
L Thermocouple
N Thm'cple Nicrosil/NiSil
R Thm'cple Pt/Pt13%Rh
S Thm'cple Pt/Pt10%Rh
B Thm'cple Pt/Pt30%Rh -6%Rh
Platinel II Thm'cple
*C Thm'cple W5%Re/W26%Re
RTD/PT100 DIN 43760
D Thm'cple W3%Re/W25%Re
E Thermocouple
Ni/Ni18%Mo Thm'cple

3
4
5
6
7
8
M
F
Y
A
W
G
V
X

Pt20%Rh/Pt40%Rh Thm'cple
W/W26%Re Thm'cple
W/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
Pt10%Rh/Pt40%Rh Thm'cple
Exegen K80 I.R.Pyrometer
-12 to 80mV Linear
-100 to 100mV Linear
0 to 20mA Linear
4 to 20mA Linear
0 to 5Vdc Linear
1 to 5Vdc Linear
1 to 10Vdc Linear

I/P 2 FUNCTION

XX
LO
HI

Default Config
No Func.IP for Monitor & Alarm
Proc Value=Lowest of IP1 & IP2

FN
RS

Proc Value=Highest of IP1 &IP1
Proc Value Derived from IP1 &1

RANGE MINIMUM

 *

User defined range

   

RANGE MAXIMUM

 *

User defined range

   

OPTIONS

XX
MP

None Specified
Melt Pressure, sensor config

SG

Strain Gauge config

print this page