1.888.550.6829   Supplier Inquiry   About Us      
CTH Controls
 
 
CTH Controls
2404 Single Loop Controller Configurator
6100XIO Paperless Chart Recorder Configurator
Option Values Description Values Description

Model

2404

1/4th DIN Base Model

 2404f

Profibus Model

FUNCTION

CC
CG
CP
P4
CM
VC
VG
VP

Controller
Single 8-Seg Program
Single 16-Seg Program
Four Programs (not for 2404f)
20 Programs
Valve Positioner
VP Single 8-Seg Program
VP Single 16-Seg Program

V4
VM
NF
NG
NP
N4
NM
NS

VP/4-Programs
VP/20-Programs (not for 2404f)
On/Off Controller
1X8 Seg Programmer
1X16 Seg Programmer
4X16 Seg Programmer
20X16 Seg Prog (not for 2404f)
Carbon Control (see non-standard field)

SUPPLY VOLTAGE

VH

85 to 264Vac

VL

19 to 29Vac/dc

MODULE 1

R2
RH
RU
R4
YH
FH
FL
DB
DL
DH
L2
LH
M1
M2
T2
TH
TU
D4
H6
H7

Relay Fitted Unconfigured
Relay PID Heating
Valve Raise Output
Form C Fitted Unconfigured
Form C PID Heating
High Alarm
Low Alarm
Deviation Band Alarm
Deviation Low Alarm
Deviation High Alarm
Logic Fitted Unconfigured
PID Heating
PDSIO Mode 1
PDSIO Mode 2
Triac Fitted Unconfigured
PID Heating
Valve Raise Output
DC output Fitted Isolated
0 to 20mA PID Heating Isolated
4 to 20mA PID Heating Isolated

H8
H9
HZ
TL
TP
TK
RR
RD
RM
TT
TD
TM
LR
LD
LT
GD
XX
RP
LO

0 to 5V PID Heating Isolated
1 to 5V PID Heating Isolated
0 to 10V PID Heating Isolated
Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
Dual Relay Fitted Unconfigured
PID Heat and Cool
VP Raise and Lower OP's
Dual Triac Fitted Unconfigured
Triac PID Heat and Cool
VP Raise and Lower OP's
Fitted Unconfigured
logic+relay PID Heat & Cool
Fitted Unconfigured
PID Heat and Cool
None
Valve Raise (With Profibus)
Isolated Logic Output

MODULE 2

R2
RC
RW
R4
YC
PO
PE
FH
FL
DB
DL
DH
RR
PP
L2
LC
T2
TC

Relay Fitted Unconfigured
Relay PID Cooling
Valve Lower Output
Form C Fitted Unconfigured
PID Cooling
Program Output 1
Program End O/P
High Alarm 2
Low Alarm 2
Deviation Band Alarm 2
Deviation Low Alarm 2
Deviation High Alarm 2
Dual Relay Fitted Unconfigured
Program Outputs 1 & 2
Logic Fitted Unconfigured
PID Cooling
Fitted Unconfigured
PID Cooling

D6
XX
LO
D4
C6
C7
C8
C9
CZ
TL
TP
TK
MS
VS
VU
VR
TW
RL

Fitted Unconfigured
None
Isolated Logic Output
DC output Fitted Isolated
0 to 20mA PID Cooling Isolated
4 to 20mA PID Cooling Isolated
0 to 5V PID Cooling Isolated
1 to 5V PID Cooling Isolated
0 to 10V PID Cooling Isolated
Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
24Vdc Transmitter PSU
VP Pot I/P Feedback
VP Pot I/P Unconfigured
VP Pot I/P Setpoint
Valve Lower Output
Valve Lower (with Profibus)

MODULE 3

R2
R4
PO
PE
FH
FL
DB
DL
DH
L2
T2
D2
RR
PP

Relay Fitted Unconfigured
Relay Fitted Unconfigured
Program Output 4
Program End O/P
High Alarm 3
Low Alarm 3
Deviation Band Alarm 3
Deviation Low Alarm 3
Deviation High Alarm 3
Logic Fitted Unconfigured
Triac Fitted Unconfigured
DC output Fitted non-Isolated
Dual Relay Fitted Unconfigured
Program Outputs 4 & 5

TL
TP
TK
MS
VS
VU
VR
W2
W5
D5
WP
D6
XX
LO

Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
24Vdc Transmitter
VP Pot I/P Feedback
VP Pot I/P Unconfigured
VP Pot I/P Setpoint
4 to 20mA Setpoint
0 to 10V Setpoint
DC I/P UNCONF.
Second PV I/P
Retransmission output Isolated
None
Isolated Logic Output

ALARM RELAY

RF
FH
FL
DB
DL
DH
RA

Relay Fitted Unconfigured
High Alarm
Low Alarm
Deviation Band Alarm
Deviation Low Alarm
Deviation High Alarm
Rate of Change

LF
HF
SF
PO
PE
XX

PDSIO Load Failure
PDSIO Heater Failure
PDSIO SSR Failure
Program Output 6
Program End O/P
None

COMMS 1

A2
AM
AE
F2
FM
FE
PB

RS232 Fitted Unconfigured
RS232 Modbus Protocol
RS232 EI Bisynch Protocol
RS422 Fitted Unconfigured
RS422 Modbus Protocol
RS422 EI Bisynch Protocol
Profibus Module (requires 2404F)

Y2
YM
YE
XX
DN
M7

RS485 Fitted Unconfigured
RS485 Modbus Protocol
RS485 EI Bisynch Protocol
None
DeviceNet
Fitted Unconfigured

COMMS 2

M6
RS
M7
PT

Fitted Unconfigured
Setpoint Input
Fitted Unconfigured
PV Retrans

TS
OT
XX

Setpoint Retrans
Output Retrans
None

MANUAL

ENG

English

 

 

NON-STANDARD

ES0209
ES0288

Zirconia for Carbon Control
Zirconia and Profibus

Requires
Requires

Mod3 = D5 / Alarm Relay = RF
Comms = PB / Mod3 = D5 / Alarm Relay = RF

PRE CONFIGURATION

Option Values Description Values Description

Model

2404

1/4th DIN Base Model

 2404f

Profibus Model

SENSOR INPUT

1
2
3
4
5
6
7
8
A
B
C
D
E
F
G

Ni/Ni18%Mo Thm'cplev
Pt20%Rh/Pt40%Rh Thm'cple
W/W26%Re Thm'cple
W/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
Pt10%Rh/Pt40%Rh Thm'cple
Exegen K80 I.R.Pyrometer
4 to 20mA Linear
B Thm'cple Pt/Pt30%Rh -6%Rh
*C Thm'cple W5%Re/W26%Re
D Thm'cple W3%Re/W25%Re
E Thermocouple
-100 to +100mV Linear
1 to 5Vdc Linear

J
K
L
M
N
P
R
S
T
V
W
X
Y
Z

J Thermocouple
K Thermocouple
L Thermocouple
-12 to 80mV Linear
N Thm'cple Nicrosil/NiSil
Platinel II Thm'cple
R Thm'cple Pt/Pt13%Rh
S Thm'cple Pt/Pt10%Rh
T Thermocouple
1 to 10Vdc Linear
1 to 5Vdc Linear
Non Standard
1 to 20mA Linear
RTD/PT100 DIN 43759

MINIMUM RANGE

 * User defined range

MAXIMUM RANGE

 * User defined range

DISPLAY UNITS

C
F

Centigrade
Fahrenheit

K
X

Kelvin
Blank

DIGITAL INPUT 1

XX
AM
SR
S2
EH
AC
PV
RP
RN
HO
RE
RH
KL
NT
TN
HB
P2

Disabled
Manual Select
Remote Setpoint Select
Second Setpoint
Integral Hold
Alarm Acknowledge
Select PV2
S'Pnt Rate Limit Enable
Run Program
Hold Program
Reset Program
Run/Hold Program
Keylock
Run/Reset
Reset/Run
Program Holdback Enable
PID 2 Select

ST
AT
FA
RB
LB
SB
PR
B1
B2
B3
B4
B5
B6
SY
SC
SG
AG

One Shot Tune Enable
Adaptive Tune Enable
Select Full Access Level
Up Button
Down Button
Scroll Button
Page Button
Least Significant BCD Digit
2nd BCD Digit
3rd BCD Digit
4th BCD Digit
5th BCD Digit
Most Significant BCD Digit
Standby-All O/P'S OFF
Program Wait at end of Segment
Skip Segment
Advance To End Of Segment

DIGITAL INPUT 2

XX
AM
SR
S2
EH
AC
PV
RP
RN
HO
RE
RH
KL
NT
TN
HB
P2

Disabled
Manual Select
Remote Setpoint Select
Second Setpoint
Integral Hold
Alarm Acknowledge
Select PV2
S'Pnt Rate Limit Enable
Run Program
Hold Program
Reset Program
Run/Hold Program
Keylock
Run/Reset
Reset/Run
Program Holdback Enable
PID 2 Select

ST
AT
FA
RB
LB
SY
PR
B1
B2
B3
B4
B5
B6
SY
SC
SG
AG

One Shot Tune Enable
Adaptive Tune Enable
Select Full Access Level
Up Button
Down Button
Scroll Button
Page Button
Least Significant BCD Digit
2nd BCD Digit
3rd BCD Digit
4th BCD Digit
5th BCD Digit
Most Significant BCD Digit
Standby-All O/P'S OFF
Program Wait at end of Segment
Skip Segment
Advance To End Of Segment

OPTIONS 1 (2404)
OPTIONS 2 (2404f)

XX
DP

None
Direct Acting PID Ctrl.

XX
PD

None
Power Feedback Disabled

OPTIONS 3 (2404)
OPTIONS 4 (2404f)

XX
CF
CW
CL
CO

None
Fan Cooling
Water Cooling
Oil Cooling
On/Off Cooling

XX
MD
RD
MR

None
Auto/Man Button Disabled
Run/Hold Button Disabled
Auto/Man & Run/Hold Disabled

OPTIONS 5

XX
HD

None
Dwell Time In Hours

HR
HT

Ramp Rate in Units/Hour
Dwell & Ramp in Hours

 