Field
|
Option
|
Description
|
Code
|
1
|
CHANNELS
|
6
Channel
|
6
|
2
|
FIXED
FIELD
|
Default
|
0
|
3
|
POWER
SUPPLY
|
90-264Vac
45-65Hz
24-48Vdc,
45-400Hz
|
1
2
|
4
|
CASSETTE
TYPE
|
Z-Fold
Cassette (16m)
Roll
Cassette (32m)
No
Cassette
|
Z
R
9
|
5
|
FIXED
FIELD
|
Default
|
0
|
6
|
CHART
DIVISION
|
50
Division
40
Division
60
Division
70
Division
75
Division
45
Division
No
Chart
|
50
40
60
70
75
45
00
|
7
|
QTY
0F SHUNTS
|
No
Shunts
1 Shunt Resistor
2 Shunt Resistor
3 Shunt Resistor
4 Shunt Resistor
5 Shunt Resistor
6 Shunt Resistor6
|
0
1
2
3
4
5
6
|
8
|
SHUNT
VALUE
|
No
Shunts
100
Ohm Shunts
250
Ohm Shunts
|
0
1
2
|
9
|
QTY
OF 100:1 ATTENUATORS
|
None
One
100:1 Attenuator
Two
100:1 Attenuators
Three
100:1 Attenuators
Four
100:1 Attenuators
Five 100:1 Attenuators
Six 100:1 Attenuators
|
0
1
2
3
4
5
6
|
10
|
FIXED
FIELD
|
Default
|
0
|
11
|
FIXED
FIELD
|
Default
|
0
|
12
|
FIXED
FIELD
|
Default
|
0
|
13
|
OPERATING
LANGUAGE
|
English
French
German
|
E
F
G
|
14
|
MANUAL
LANGUAGE
|
English
French
German
None
|
E
F
G
0
|
15
|
CHAR ILLUMINATION
|
Chart Illumination Not Fitted
|
0
|
16
|
FIXED
FIELD
|
Default
|
0
|
17
|
FIXED
FIELD
|
Default
|
0
|
18
|
FIXED
FIELD
|
Default
|
0
|
19
|
FIXED
FIELD
|
Default
|
01
|
20
|
FIXED
FIELD
|
Default
|
0
|
21
|
DOOR
MATERIAL
|
Polycarbonate
|
P
|
22
|
CALIBRATION
CERT
*See
note 3
|
|
0
|
23
|
OPTIONS
|
None
Portability
Option
Long
Terminal cover no TRS
Conformal Coating
|
000
001
013
TRP
|
24
|
FIXED
FIELD
|
Default
|
X
|
25
|
FIXED
FIELD
|
Default
|
0
|
26
|
FIXED
FIELD
|
Default
|
0
|
27
|
RELAYS
CHANGE OVER IN ALARM
*See
note 2
|
No
CO Relay Outputs
3
CO Relay Outputs (1 PCB)
6
CO Relay Outputs (2 PCB)
9
CO Relay Outputs (3 PCB)
12
CO Relay Outputs (4 PCB)
|
0
1
2
3
4
|
28
|
FIXED
FIELD
|
Default
|
0
|
29
|
EVENT
INPUTS
*See
note 2
|
Event
Inputs Not Fitted
6
Events Inputs (1 PCB)
|
0
E
|
30
|
MEMORY
CARD DRIVER
|
Default
SW opt key
Config
Save & Restore
ASCII
Logging
Packed
Logging - inc PC s/w
|
K
C
A
P
|
31
|
MEMORY
CARD SIZE
|
No
Memory Card
2
Mb Memory Card
6
Mb Memory Card
|
0
3
6
|
32
|
COMMUNICATIONS
|
Not
Required
RS485
+ Modbus RTU
RS232
+ Modbus RTU
RS232
+ File Transfer
RS485
+ FILE TRANSFER
|
0
1
3
4
6
|
33
|
FIXED
FIELD
|
Default
|
0
|
34
|
SOFTWARE
OPTIONS FITTED
*See
note 3
|
No
Software Options
Software
Options Fitted
|
0
1
|
35
|
FIXED
FIELD
|
Default
|
0
|
36
|
CUSTOM
MESSAGES
|
None
Custom
Messages
|
0
M
|
37
|
MATHS
PACK
|
Maths
Pack Not Fitted
Basic
Maths Pack Fitted
Advanced
Maths Pack
Adv.Maths,Exp.
|
0
1
2
3
|
38
|
TOTALISER'S
,TIMER'S & COUNTER'S
|
No
Totaliser,Timer,Counter
6
Totalisers/Timers/Counters
Two
Totaliser's
Four
Totaliser's
Six
Totaliser's
Six
Timers & Six Counters
|
0
T
2
4
6
C
|
39
|
CUSTOM
CURVE
|
Custom
Curve Not Fitted
Custom
Curve Fitted
|
0
1
|