Action ULTRA SLIMPAK® II WV118 DC Powered RTD Input Limit Alarm

Provides Relay Contact Closures at a Preset Temperature Level.


Features:
  • Programmable HI or LO, Failsafe or Non-failsafe
  • Improved Accuracy
  • Adjustable Deadband
  • Bussed Power with Plug-in Power Clips
  • Removable Terminals for Easy Service
  • Touch Cal for Best Stability and Accuracy
  • RoHS Compliant
  • LED Trip and Input Indicators
  • Optional E-mail Notification of Alarms
  • Supports 2-Wire and 3-Wire RTDs

WV118-2000 (non-latching)
WV118-2001 (latching)

Description
The Ultra SlimPak II is an exciting new line of isolating signal conditioners from Action Instruments with greater accuracy and better stability than virtually any other signal conditioners on the market today.

The WV118 is an RTD Limit Alarm with dual setpoints and two contact closure outputs. The input type and alarm functions are field configurable, offering maximum flexibility. The WV118 sup- ports Pt100, in both 0.00385 and 0.00392 alphas, and Cu10 RTDs. All ranges allow the setpoints to be fully adjustable throughout the entire range.

The WV118-2000 contains two standard non-latching SPDT relays. When power is removed, the relays revert to their non-powered state. The WV118-2001 contains two latching relays. Whatever position the relays are in when power is removed is where they will remain when power is re-applied (a reset switch is provided to reset the relays after the alarm is no longer true). Both models are configurable as a single or dual setpoint alarm, with HI or LO trips. The WV118-2000 supports failsafe or non-failsafe operation. In failsafe operation the relay coil is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non- failsafe). In the failsafe mode, a power failure results in an alarm state output.

Operation
Each of the alarm setpoints has a respective HI or LO deadband. Red LEDs will illuminate indicating an alarm condition. The trip will reset only when the process falls below the HI deadband or rises above the LO deadband. (The WV118-2001 requires pressing the reset switch in order to reset the relay after being tripped.) The deadband can be left at the minimum level (the factory default) or can be set to whatever level is desired.

Click here for the complete information in .pdf format

 

 
 
CTH Controls Inc.   CTH Controls Inc.
5100 South Service Road, Unit 2
Burlington, ON. L7L 6A5 Canada
Phone: 905-792-6829
Toll Free: 1-888-550-6829
Fax: 905-792-6902
sales@cthcontrols.com
  arrow Products arrow Contact Us  

For Secure Payments
Mastercard Visa
<empty> <empty> <empty>
<empty>
PAYPAL
PAYMENT
GUIDE
<empty>
<empty> <empty> <empty>
  arrow Services arrow Supplier Inquiry  
  arrow Support arrow ISO Certification  
  arrow About Us arrow Return Policy  
    arrow Careers  
  arrow Line Card  
© Copyright 1998-2024, CTH Controls Inc. All rights reserved