Action ULTRA SLIMPAK® G128-0001 DC Powered T/C Input Limit Alarm

Provides Relay Contact Closures at a Preset Temperature Input Level.


Features:
  • Programmable HI or LO, Failsafe or Non-failsafe
  • Field Configurable Input Ranges
  • LED Trip and Input Indicators
  • Flexible Power Supply Accepts 9 to 30 VDC
  • ASIC Technology for Enhanced Reliability
  • RoHS Compliant

G128-0001

Description
The Ultra Slim Pak G128 is a DIN rail mount, thermocouple input limit alarm with input terminal cold junction compensation (cjc), dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint capability. There are up to six temperature ranges available for each thermocouple type to ensure accuracy and maximize setpoint resolution.

The G128 is configurable as a single or dual setpoint alarm, with HI or LO trips, upscale or downscale thermocouple burnout detection and failsafe or non-failsafe operation. Also included are adjustable deadbands (0.25 to 5% of full scale input) for each setpoint and a flexible DC power supply which accepts any voltage between 9 and 30VDC.

Operation
The field configurable G128 limit alarm setpoints can be config- ured for HI or LO, failsafe or non-failsafe operation. Each of the setpoints has a respective HI or LO deadband. In a tripped condition, the setpoint is exceeded and the appropriate red LED will illuminate. The trip will reset only when the process falls below the HI deadband or rises above the LO deadband. For proper deadband operation, the HI setpoint must always be set above the LO setpoint. In failsafe operation, the relay is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non-failsafe). In the failsafe mode, a power failure results in an alarm state output.

Click here for the complete information in .pdf format

 

 
 
CTH Controls Inc.   CTH Controls Inc.
5100 South Service Road, Unit 2
Burlington, ON. L7L 6A5 Canada
Phone: 905-792-6829
Toll Free: 1-888-550-6829
Fax: 905-792-6902
sales@cthcontrols.com
  arrow Products arrow Contact Us  

For Secure Payments
Mastercard Visa
<empty> <empty> <empty>
<empty>
PAYPAL
PAYMENT
GUIDE
<empty>
<empty> <empty> <empty>
  arrow Services arrow Supplier Inquiry  
  arrow Support arrow ISO Certification  
  arrow About Us arrow Return Policy  
    arrow Careers  
  arrow Line Card  
© Copyright 1998-2024, CTH Controls Inc. All rights reserved