Option |
Values |
Description |
Values |
Description |
Model |
2408 |
1/4th DIN Base Model |
2408f |
Profibus Model |
FUNCTION |
CC
CG
CP
P4
CM
VC
VG
VP |
Controller
Single 8-Seg Program
Single 16-Seg Program
Four Programs
20 Programs (not for 2408f)
Valve Positioner
VP Single 8-Seg Program
VP Single 16-Seg Program |
V4
VM
NF
NG
NP
N4
NM
|
VP/4-Programs
VP/20-Programs (not for 2408f)
On/Off Controller
1X8 Seg Programmer
1X16 Seg Programmer
4X16 Seg Programmer
20X16 Seg Programmer (not for 2408f)
|
SUPPLY VOLTAGE |
VH |
85 to 264Vac |
VL |
19 to 29Vac/dc |
MODULE 1 |
R2
RH
RU
R4
YH
FH
FL
DB
DL
DH
L2
LH
M1
M2
T2
TH
TU
D4
H6
H7 |
Relay Fitted Unconfigured
Relay PID Heating
Valve Raise Output
Fitted Unconfigured
PID Heating
High Alarm
Low Alarm
Deviation Band Alarm
Deviation Low Alarm
Deviation High Alarm
Logic Fitted Unconfigured
Logic PID Heating
PDSIO Mode 1
PDSIO Mode 2
Fitted Unconfigured
Triac PID Heating
Valve Raise Output
DC output Fitted Unconfigured
0 to 20mA PID Heating
4 to 20mA PID Heating |
H8
H9
HZ
TL
TP
TK
RR
RD
RM
TT
TD
TM
LR
LD
LT
GD
XX
G3
G5
LO |
0 to 5V PID Heating
1 to 5V PID Heating
0 to 10V PID Heating
Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
Dual Relay Fitted Unconfigured
PID Heat and Cool
VP Raise and Lower OP's
Dual Triac Fitted Unconfigured
Triac PID Heat and Cool
VP Raise and Lower OP's
Logic/Relay Fitted Unconfigured
logic+relay PID Heat & Cool
Fitted Unconfigured
PID Heat and Cool
None
OP Voltage 5V
OP Voltage 10V
Isolated Logic Output |
MODULE 2 |
R2
RC
RW
R4
YC
PO
PE
FH
FL
DB
DL
DH
RR
PP
L2
LC
T2
TC
TW |
Relay Fitted Unconfigured
Relay PID Cooling
Relay Valve Lower Output
Form C Relay Unconfigured
Form C Relay PID Cooling
Program Output 1
Program End O/P
High Alarm 2
Low Alarm 2
Deviation Band Alarm 2
Deviation Low Alarm 2
Deviation High Alarm 2
Dual Relay Fitted Unconfigured
Program Outputs 1 & 2
Logic Fitted Unconfigured
Logic PID Cooling
Triac Fitted Unconfigured
Triac PID Cooling
Valve Lower Output |
D4
C6
C7
C8
C9
CZ
G3
G5
LO
TL
TP
TK
MS
VS
VU
VR
D6
XX |
Fitted Unconfigured
0 to 20mA PID Cooling
4 to 20mA PID Cooling
0 to 5V PID Cooling
1 to 5V PID Cooling
0 to 10V PID Cooling
OP Voltage 5V
OP Voltage 10V
Isolated Logic Output
Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
24Vdc Transmitter PSU
VP Pot I/P Feedback
VP Pot I/P Unconfigured
VP Pot I/P Setpoint
Fitted Unconfigured
None |
MODULE 3 |
R2
R4
PO
PE
FH
FL
DB
DL
DH
L2
T2
RR
PP |
Relay Fitted Unconfigured
Form C Fitted Unconfigured
Program Output 4
Program End O/P
High Alarm 3
Low Alarm 3
Deviation Band Alarm 3
Deviation Low Alarm 3
Deviation High Alarm 3
Logic Fitted Unconfigured
Triac Fitted Unconfigured
Dual Relay Fitted Unconfigured
Program Outputs 4 & 5 |
TL
TP
TK
MS
VS
VU
VR
W2
W5
D5
WP
D6
XX
LO |
Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
24Vdc Transmitter
VP Pot I/P Feedback
VP Pot I/P Unconfigured
VP Pot I/P Setpoint
4 to 20mA Setpoint
0 to 10V Setpoint
DC intput unconfigured
Second PV I/P
Fitted Unconfigured
None
Isolated Logic Output |
ALARM RELAY |
RF
FH
FL
DB
DL
DH
RA |
Relay Fitted Unconfigured
High Alarm
Low Alarm
Deviation Band Alarm
Deviation Low Alarm
Deviation High Alarm
Rate of Change |
LF
HF
SF
PO
PE
XX
|
PDSIO Load Failure
PDSIO Heater Failure
PDSIO SSR Failure
Program Output 6
Program End O/P
None
|
COMMS 1 |
A2
AM
AE
F2
FM
FE
PB |
RS232 Fitted Unconfigured
RS232 Modbus Protocol
RS232 EI Bisynch Protocol
RS422 Fitted Unconfigured
RS422 Modbus Protocol
RS422 EI Bisynch Protocol
Profibus High Speed Comms |
Y2
YM
YE
XX
DN
M7 |
RS485 Fitted Unconfigured
RS485 Modbus Protocol
RS485 EI Bisynch Protocol
None
DeviceNet
Fitted Unconfigured |
COMMS 2 |
M6
RS
M7
PT |
Fitted Unconfigured
Setpoint Input
Fitted Unconfigured
PV Retrans |
TS
OT
XX |
Setpoint Retrans
Output Retrans
None |
MANUAL |
ENG |
English |
|
|
SENSOR INPUT |
1
2
3
4
5
6
7
8
A
B
C
D
E
F
G |
Ni/Ni18%Mo Thm'cplev
Pt20%Rh/Pt40%Rh Thm'cple
W/W26%Re Thm'cple
W/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
Pt10%Rh/Pt40%Rh Thm'cple
Exegen K80 I.R.Pyrometer
4 to 20mA Linear
B Thm'cple Pt/Pt30%Rh -6%Rh
*C Thm'cple W5%Re/W26%Re
D Thm'cple W3%Re/W25%Re
E Thermocouple
-100 to +100mV Linear
1 to 5Vdc Linear |
J
K
L
M
N
P
R
S
T
V
W
X
Y
Z |
J Thermocouple
K Thermocouple
L Thermocouple
-12 to 80mV Linear
N Thm'cple Nicrosil/NiSil
Platinel II Thm'cple
R Thm'cple Pt/Pt13%Rh
S Thm'cple Pt/Pt10%Rh
T Thermocouple
1 to 10Vdc Linear
1 to 5Vdc Linear
Non Standard
1 to 20mA Linear
RTD/PT100 DIN 43759 |
MINIMUM RANGE |
* |
User defined range |
|
|
MAXIMUM RANGE |
* |
User defined range |
|
|
DISPLAY UNITS |
C
F |
Centigrade
Fahrenheit |
K
X |
Kelvin
Blank |
DIGITAL INPUT 1 |
XX
AM
SR
S2
EH
AC
PV
RP
RN
HO
RE
RH
KL
NT
TN
HB
P2
|
Disabled
Manual Select
Remote Setpoint Select
Second Setpoint
Integral Hold
Alarm Acknowledge
Select PV2
S'Pnt Rate Limit Enable
Run Program
Hold Program
Reset Program
Run/Hold Program
Keylock
Run/Reset
Reset/Run
Program Holdback Enable
PID 2 Select |
ST
AT
FA
RB
LB
SB
PR
B1
B2
B3
B4
B5
B6
SY
SC
SG
AG |
One Shot Tune Enable
Adaptive Tune Enable
Select Full Access Level
Up Button
Down Button
Scroll Button
Page Button
Least Significant BCD Digit
2nd BCD Digit
3rd BCD Digit
4th BCD Digit
5th BCD Digit
Most Significant BCD Digit
Standby-All O/P'S OFF
Program Wait at end of Segment
Skip Segment
Advance To End Of Segment |
DIGITAL INPUT 2 |
XX
AM
SR
S2
EH
AC
PV
RP
RN
HO
RE
RH
KL
NT
TN
HB
P2 |
Disabled
Manual Select
Remote Setpoint Select
Second Setpoint
Integral Hold
Alarm Acknowledge
Select PV2
S'Pnt Rate Limit Enable
Run Program
Hold Program
Reset Program
Run/Hold Program
Keylock
Run/Reset
Reset/Run
Program Holdback Enable
PID 2 Select |
ST
AT
FA
RB
LB
SY
PR
B1
B2
B3
B4
B5
B6
SY
SC
SG
AG |
One Shot Tune Enable
Adaptive Tune Enable
Select Full Access Level
Up Button
Down Button
Scroll Button
Page Button
Least Significant BCD Digit
2nd BCD Digit
3rd BCD Digit
4th BCD Digit
5th BCD Digit
Most Significant BCD Digit
Standby-All O/P'S OFF
Program Wait at end of Segment
Skip Segment
Advance To End Of Segment |
OPTIONS 1 (2408)
OPTIONS 2 (2408f) |
XX
DP |
None
Direct Acting PID Ctrl. |
XX
PD |
None
Power Feedback Disabled |
OPTIONS 3 (2408)
OPTIONS 4 (2408f) |
XX
CF
CW
CL
CO |
None
Fan Cooling
Water Cooling
Oil Cooling
On/Off Cooling |
XX
MD
RD
MR |
None
Auto/Man Button Disabled
Run/Hold Button Disabled
Auto/Man & Run/Hold Disabled |
OPTIONS 5 |
XX
HD |
None
Dwell Time In Hours |
HR
HT |
Ramp Rate in Units/Hour
Dwell & Ramp in Hours |