2408 Single Loop Controller Configurator
6100XIO Paperless Chart Recorder Configurator
Option Values Description Values Description

Model

2408

1/4th DIN Base Model

 2408f

Profibus Model

FUNCTION

CC
CG
CP
P4
CM
VC
VG
VP

Controller
Single 8-Seg Program
Single 16-Seg Program
Four Programs
20 Programs (not for 2408f)
Valve Positioner
VP Single 8-Seg Program
VP Single 16-Seg Program

V4
VM
NF
NG
NP
N4
NM

VP/4-Programs
VP/20-Programs (not for 2408f)
On/Off Controller
1X8 Seg Programmer
1X16 Seg Programmer
4X16 Seg Programmer
20X16 Seg Programmer (not for 2408f)

SUPPLY VOLTAGE

VH

85 to 264Vac

VL

19 to 29Vac/dc

MODULE 1

R2
RH
RU
R4
YH
FH
FL
DB
DL
DH
L2
LH
M1
M2
T2
TH
TU
D4
H6
H7

Relay Fitted Unconfigured
Relay PID Heating
Valve Raise Output
Fitted Unconfigured
PID Heating
High Alarm
Low Alarm
Deviation Band Alarm
Deviation Low Alarm
Deviation High Alarm
Logic Fitted Unconfigured
Logic PID Heating
PDSIO Mode 1
PDSIO Mode 2
Fitted Unconfigured
Triac PID Heating
Valve Raise Output
DC output Fitted Unconfigured
0 to 20mA PID Heating
4 to 20mA PID Heating

H8
H9
HZ
TL
TP
TK
RR
RD
RM
TT
TD
TM
LR
LD
LT
GD
XX
G3
G5
LO

0 to 5V PID Heating
1 to 5V PID Heating
0 to 10V PID Heating
Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
Dual Relay Fitted Unconfigured
PID Heat and Cool
VP Raise and Lower OP's
Dual Triac Fitted Unconfigured
Triac PID Heat and Cool
VP Raise and Lower OP's
Logic/Relay Fitted Unconfigured
logic+relay PID Heat & Cool
Fitted Unconfigured
PID Heat and Cool
None
OP Voltage 5V
OP Voltage 10V
Isolated Logic Output

MODULE 2

R2
RC
RW
R4
YC
PO
PE
FH
FL
DB
DL
DH
RR
PP
L2
LC
T2
TC
TW

Relay Fitted Unconfigured
Relay PID Cooling
Relay Valve Lower Output
Form C Relay Unconfigured
Form C Relay PID Cooling
Program Output 1
Program End O/P
High Alarm 2
Low Alarm 2
Deviation Band Alarm 2
Deviation Low Alarm 2
Deviation High Alarm 2
Dual Relay Fitted Unconfigured
Program Outputs 1 & 2
Logic Fitted Unconfigured
Logic PID Cooling
Triac Fitted Unconfigured
Triac PID Cooling
Valve Lower Output

D4
C6
C7
C8
C9
CZ
G3
G5
LO
TL
TP
TK
MS
VS
VU
VR
D6
XX

Fitted Unconfigured
0 to 20mA PID Cooling
4 to 20mA PID Cooling
0 to 5V PID Cooling
1 to 5V PID Cooling
0 to 10V PID Cooling
OP Voltage 5V
OP Voltage 10V
Isolated Logic Output
Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
24Vdc Transmitter PSU
VP Pot I/P Feedback
VP Pot I/P Unconfigured
VP Pot I/P Setpoint
Fitted Unconfigured
None

MODULE 3

R2
R4
PO
PE
FH
FL
DB
DL
DH
L2
T2

RR
PP

Relay Fitted Unconfigured
Form C Fitted Unconfigured
Program Output 4
Program End O/P
High Alarm 3
Low Alarm 3
Deviation Band Alarm 3
Deviation Low Alarm 3
Deviation High Alarm 3
Logic Fitted Unconfigured
Triac Fitted Unconfigured

Dual Relay Fitted Unconfigured
Program Outputs 4 & 5

TL
TP
TK
MS
VS
VU
VR
W2
W5
D5
WP
D6
XX
LO

Fitted Unconfigured
Fitted Unconfigured
Triple Contact I/P
24Vdc Transmitter
VP Pot I/P Feedback
VP Pot I/P Unconfigured
VP Pot I/P Setpoint
4 to 20mA Setpoint
0 to 10V Setpoint
DC intput unconfigured
Second PV I/P
Fitted Unconfigured
None
Isolated Logic Output

ALARM RELAY

RF
FH
FL
DB
DL
DH
RA

Relay Fitted Unconfigured
High Alarm
Low Alarm
Deviation Band Alarm
Deviation Low Alarm
Deviation High Alarm
Rate of Change

LF
HF
SF
PO
PE
XX

PDSIO Load Failure
PDSIO Heater Failure
PDSIO SSR Failure
Program Output 6
Program End O/P
None

COMMS 1

A2
AM
AE
F2
FM
FE
PB

RS232 Fitted Unconfigured
RS232 Modbus Protocol
RS232 EI Bisynch Protocol
RS422 Fitted Unconfigured
RS422 Modbus Protocol
RS422 EI Bisynch Protocol
Profibus High Speed Comms

Y2
YM
YE
XX
DN
M7

RS485 Fitted Unconfigured
RS485 Modbus Protocol
RS485 EI Bisynch Protocol
None
DeviceNet
Fitted Unconfigured

COMMS 2

M6
RS
M7
PT

Fitted Unconfigured
Setpoint Input
Fitted Unconfigured
PV Retrans

TS
OT
XX

Setpoint Retrans
Output Retrans
None

MANUAL

ENG

English

 

 

SENSOR INPUT

1
2
3
4
5
6
7
8
A
B
C
D
E
F
G

Ni/Ni18%Mo Thm'cplev
Pt20%Rh/Pt40%Rh Thm'cple
W/W26%Re Thm'cple
W/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
Pt10%Rh/Pt40%Rh Thm'cple
Exegen K80 I.R.Pyrometer
4 to 20mA Linear
B Thm'cple Pt/Pt30%Rh -6%Rh
*C Thm'cple W5%Re/W26%Re
D Thm'cple W3%Re/W25%Re
E Thermocouple
-100 to +100mV Linear
1 to 5Vdc Linear

J
K
L
M
N
P
R
S
T
V
W
X
Y
Z

J Thermocouple
K Thermocouple
L Thermocouple
-12 to 80mV Linear
N Thm'cple Nicrosil/NiSil
Platinel II Thm'cple
R Thm'cple Pt/Pt13%Rh
S Thm'cple Pt/Pt10%Rh
T Thermocouple
1 to 10Vdc Linear
1 to 5Vdc Linear
Non Standard
1 to 20mA Linear
RTD/PT100 DIN 43759

MINIMUM RANGE   * User defined range    
MAXIMUM RANGE   * User defined range    

DISPLAY UNITS

C
F

Centigrade
Fahrenheit

K
X

Kelvin
Blank

DIGITAL INPUT 1

XX
AM
SR
S2
EH
AC
PV
RP
RN
HO
RE
RH
KL
NT
TN
HB
P2

Disabled
Manual Select
Remote Setpoint Select
Second Setpoint
Integral Hold
Alarm Acknowledge
Select PV2
S'Pnt Rate Limit Enable
Run Program
Hold Program
Reset Program
Run/Hold Program
Keylock
Run/Reset
Reset/Run
Program Holdback Enable
PID 2 Select

ST
AT
FA
RB
LB
SB
PR
B1
B2
B3
B4
B5
B6
SY
SC
SG
AG

One Shot Tune Enable
Adaptive Tune Enable
Select Full Access Level
Up Button
Down Button
Scroll Button
Page Button
Least Significant BCD Digit
2nd BCD Digit
3rd BCD Digit
4th BCD Digit
5th BCD Digit
Most Significant BCD Digit
Standby-All O/P'S OFF
Program Wait at end of Segment
Skip Segment
Advance To End Of Segment

DIGITAL INPUT 2

XX
AM
SR
S2
EH
AC
PV
RP
RN
HO
RE
RH
KL
NT
TN
HB
P2

Disabled
Manual Select
Remote Setpoint Select
Second Setpoint
Integral Hold
Alarm Acknowledge
Select PV2
S'Pnt Rate Limit Enable
Run Program
Hold Program
Reset Program
Run/Hold Program
Keylock
Run/Reset
Reset/Run
Program Holdback Enable
PID 2 Select

ST
AT
FA
RB
LB
SY
PR
B1
B2
B3
B4
B5
B6
SY
SC
SG
AG

One Shot Tune Enable
Adaptive Tune Enable
Select Full Access Level
Up Button
Down Button
Scroll Button
Page Button
Least Significant BCD Digit
2nd BCD Digit
3rd BCD Digit
4th BCD Digit
5th BCD Digit
Most Significant BCD Digit
Standby-All O/P'S OFF
Program Wait at end of Segment
Skip Segment
Advance To End Of Segment

OPTIONS 1 (2408)
OPTIONS 2 (2408f)

XX
DP

None
Direct Acting PID Ctrl.

XX
PD

None
Power Feedback Disabled

OPTIONS 3 (2408)
OPTIONS 4 (2408f)

XX
CF
CW
CL
CO

None
Fan Cooling
Water Cooling
Oil Cooling
On/Off Cooling

XX
MD
RD
MR

None
Auto/Man Button Disabled
Run/Hold Button Disabled
Auto/Man & Run/Hold Disabled

OPTIONS 5

XX
HD

None
Dwell Time In Hours

HR
HT

Ramp Rate in Units/Hour
Dwell & Ramp in Hours

 