2216e, 2208e and 2204e Single Loop Controller Configurator
6100XIO Paperless Chart Recorder Configurator
Option Values Value Descriptions

Model Options

2204E
2208E
2216E

1/4th DIN Base Modelv
1/8th DIN Base Model
1/16th DIN Base Model

FUNCTION

VC
AL
CC
NF

VALVE POSITIONER
ALARM UNIT
CONTROLLER
ON/OFF CONTROLLER

SUPPLY VOLTAGE

VH

85 TO 264 VAC

OUTPUT 1

R1
RH
RU
FH
FL
DB
DL
DH
L1
LH
M1
M2
T1
TH
TU
D6
C6
C7
D3
H6
H7

RELAY
RELAY PID HEATING
VP RAISE OUTPUT
HIGH ALARM RELAY
LOW ALARM RELAY
DEV BAND ALARM RELAY
DEV LOW ALARM RELAY
DEV HIGH ALARM RELAY
LOGIC OUTPUT
LOGIC PID HEATING
PDSIO Mode 1
PDSIO Mode 2
TRIAC OUTPUT
TRIAC PID HEATING
VP RAISE OUTPUT
DC Retransmission Unconfigured (See Note 1)
0 to 20mA PID COOLING (ISOLATED)
4 to 20mA PID COOLING (ISOLATED)
DC Control Output (ISOLATED)
0 to 20mA PID HEATING (ISOLATED)
4 to 20mA PID HEATING (ISOLATED)

OUTPUT 2

R1
FH
FL
DB
DL
DH
RC
RW
RH
AL
L1
LC
LH
AM
S2
AC
SB
T1
TC
TW
TH
XX

RELAY-UNCONFIGURED
HIGH ALARM RELAY 2
LOW ALARM RELAY 2
DEV BAND ALARM RELAY 2
DEV LOW ALARM RELAY 2
DEV HIGH ALARM RELAY 2
RELAY PID COOLING
VP LOWER OUTPUT
HEATING OUTPUT RELAY
HIGH & LOW ALARMS
LOGIC-UNCONFIGURED
LOGIC PID COOLING
LOGIC HEATING OUTPUT
AUTO/MANUAL SELECT
SETPOINT 2 SELECT
ALARM ACKNOWLEDGE/RESET
STANDBY MODE
TRIAC - UNCONFIGURED
TRIAC - PID COOLING
TRIAC - VP LOWER OUTPUT
HEATING OUTPUT TRIAC
NONE

ALARM 1 RELAY

RF
DB
DH
DL
FH
FL
HF
LF
RC
RH
SF
AL
XX

RELAY CHANGE-OVER UNCONFIGURED
DEVIATION BAND ALARM RELAY 2
DEVIATION HIGH ALARM RELAY 2
DEVIATION LOW ALARM RELAY 2
HIGH LIMIT ALARM
LOW LIMIT ALARM
HEATER FAULT - REQUIRES PDSIO MODE2
LOAD FAULT - REQUIRES PDSIO MODE1
RELAY PID COOLING
RELAY PID HEATING
SSRELAY FAULT-REQUIRES PDSIO MODE2
HIGH & LOW ALARMS 3 & 4
NONE

ALARM 2 RELAY

XX
RF
DB
DH
DL
FH
FL
RC
RH
AL

NONE
RELAY CHANGE-OVER
DEVIATION BAND ALARM RELAY 2
DEVIATION HIGH ALARM RELAY 2
DEVIATION LOW ALARM RELAY 2
HIGH LIMIT ALARM
LOW LIMIT ALARM
RELAY PID COOLING
RELAY PID HEATING
HIGH & LOW ALARMS 3 & 4

COMMUNICATIONS

2AE
2AM
2YE
2YM
2FE
2FM
2DN
2M4
2RS
2XX

EIA-232 EI BISYNCH PROTOCOL
EIA-232 MODBUS PROTOCOL
EIA-485 EI BISYNCH PROTOCOL
EIA-485 MODBUS PROTOCOL
EIA-422 EI BISYNCH PROTOCOL
EIA-422 EI MODBUS PROTOCOL
DEVICENET
PDSIO Unconfigured
PDSIO Remote Input
NONE

CUSTOM LABEL

XXXXX
F0492

No Custom Label Needed
Must choose F0492 if choosing EU0492 option

NONSTANDARDS

EU0555
EU0492
EU0511
XXXXX

MUST CHOOSE  THIS OPTION WITH D3, H6, H7, C6 or C7 (unless other non-standard is chosen)
DIN Rail with TC, mA and mV input/Modbus, Profibus and Dnet comms
DIN Rail with RTD, mA and mV input / Modbus only
Standard Unit

 
Note 1)
Retrans chart
V = PV
O = OP
Z = Error 
     3 = 0 - 5Vdc
     4 = 1 - 5 Vdc
     5 = 0 - 10Vdc